No |
Name |
|
Description |
E |
Feeding System |
|
|
|
|
|
hydraulically operated (double cylinders) feeding ram |
|
|
|
over monitored by PLC real time monitoring of motor |
|
|
|
load to optimize materials feeding
regulation and also |
|
|
|
prevent over-fed congestion that leads to rotor jam |
|
|
|
|
|
Hydraulic System (4 kW Power Pack) |
|
4.8 cc gear pump c/w motor, center block, fan cooler, |
|
|
solenoid valve, 45 liters
tank, accessories, hydraulic |
|
|
hose, fittings & 2 nos.
cylinder |
|
|
|
|
|
Feeding Ram
(Deck) |
|
mild steel deck c/w stainless steel (SS304) liner plate on |
|
|
|
deck top |
|
|
|
|
|
Feeding Ram (Movement) |
|
via guided rollers that moving along a resistant-free |
|
|
railing system |
|
|
|
F |
Standard Pre-Wired
Starter & Control Panel |
|
Type |
|
floor standing |
|
Housing |
|
outdoor weather protection metal sheet housing c/w |
|
|
double layer panel*s door |
|
Panel Board Dimension |
|
900 mm (W) x
400 mm (D) x 1800 mm (H) |
|
|
|
|
|
Programmable Logic Controller (PLC) |
|
TELEMECANIQUE (France) c/w alpha-numeric |
|
(Smart Relay 26 I/O) |
|
digital
display provides failure identification |
|
MY2 Relay 24VDC |
|
TELEMECANIQUE
(France) |
|
|
|
|
|
Current Protector |
|
|
|
Main Drive Motor |
|
225 A MCCB
25KA TP 每 TERASAKI (Japan) or |
|
|
|
equivalent |
|
Auxiliary Drive Motor (Power Pack) |
|
20 A MCB 4.5
KA TP 每 HAGER / MG (France) or |
|
|
|
equivalent |
|
Auxiliary Components |
|
6 A MCB 2P 每 HAGER or equivalent |
|
|
|
|
|
Auto Transformer |
|
|
|
Main Drive Motor |
|
132 kW c/w
reversing control 每 QPS |
|
|
|
|
|
Starter / Contactor |
|
|
|
Main Drive Motor |
|
110 kW
Auto-Trans 每 FUJI (Japan) |
|
|
|
|
|
Auxiliary Drive Motor (Power Pack) |
|
4 kW DOL 每
FUJI (Japan) |
|
|
|
|
|
Thermal Overload Relays |
|
|
|
Main Drive Motor |
|
FUJI (Japan) |
|
Auxiliary Drive Motor |
|
FUJI (Japan) |
|
|
|
|
|
Other Components |
|
step-down transformer 440 VAC to 240 VAC 400 VA |
|
|
|
power
stabilizer 240 VAC > 24VDC 2.1 A |
|
|
CT 200/5A
class 3 5VA |
|
|
current
transducer |
|
|
ammeter
& voltmeter c/w selector switch |
|
|
run/trip
indicating light |
|
|
start &
stop/reset push button |
|
|
feeding ram
forward/backward indicating light |
|
|
hour run
counter |
|
|
emergency
push button |
|
|
|
|
Proximity Sensor (Safety Switch) |
|
rotor
tilting control (motor cut-off) |
|
|
|
refuse to start without
closing rotor access door |
|
Cables |
|
outgoing
cable to main drive motor |
|
|
|
outgoing
cable to auxiliary drive motor |
|
|
|
|
|
|
|
|